Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Botucatu; s.n; 2013. 89 p. ilus, graf, tab.
Thesis in Portuguese | LILACS | ID: lil-751038

ABSTRACT

Foi descrito um modelo experimental de estudo de infusão rápida de cristaloide em ratos, discutindo-se os resultados clínicos, laboratoriais e histológicos obtidos com a administração de diferentes volumes. Utilizou-se 56 ratos machos da linhagem Wistar com peso médio de 318 g (± 4), divididos aleatoriamente em sete grupos de oito animais. Os animais dos grupos 1 ao 6 receberam solução de Ringer com lactato por via intravenosa, de maneira rápida (25 ml/min), no volume correspondente a 50%, 100%, 150%, 200%, 250% e 300% da volemia (V), respectivamente, formando os grupos de estudo. Os ratos do grupo 0 foram operados da mesma forma, mas não receberam o cristaloide, constituindo o grupo controle (SHAM). A avaliação laboratorial do sangue e dos sinais clínicos foram realizados em dois tempos (antes e dez minutos após a infusão líquida). A avaliação gravimétrica do edema pulmonar (EP) foi feita com o pulmão esquerdo e a histológica com o pulmão direito, ambos extraídos após eutanásia. As variáveis que apresentavam dois tempos foram analisadas através da diferença entre os momentos, comparando com o grupo controle por uma análise de variância, seguido do teste de Dunnet. As análises do índice pulmonar (IP), seco-úmido (ISU), histologia e desfecho foram realizadas utilizando uma análise de variância (ANOVA). O nível de significância foi fixado em 5%. Os sinais clínicos apresentaram alteração significativa a partir da hidratação com volume correspondente a 2 vezes a V. A queda na taxa de hematócrito foi significativa nos 6 grupos de estudo, confirmando a eficácia do método na promoção de hemodiluição. Os exames laboratoriais de sangue apresentaram-se alterados a partir da infusão de volume igual à V...


It was described an animal model study of crystalloid rapid infusion in rats, discussing the clinical, laboratorial and histological results acquired with the administration of various amounts. Fifty six male Wistar rats were used with a medium weight of 318 (± 4) grams, divided randomly in seven groups of eight animals. The rats of groups 1 to 6 received lactated Ringer´s solution intravenously, in a rapid way (25 ml/min), in the amount of 0.5, 1, 1.5, 2, 2.5 and 3 fold its blood volume (BV), respectively, composing the study groups. The rats of group 0 were submitted to surgery the same way, but did not receive the crystalloid, composing the control group (SHAM). The laboratorial evaluation of blood and the clinical signs were made in two times (before and ten minutes after the fluid infusion). The gravimetric assessment of pulmonary edema (PE) was made with the left lung and the histological assessment with the right lung, both extracted after euthanasia. The data with two distinct times were analyzed through the difference between the moments, comparing to the control group with an analysis of variance, followed by Dunnett´s test. The evaluation of the lung wet weight/body weight ratio (LW/BW), the lung wet/dry weight ratio (W/D), histology and upshot were performed by an analysis of variance (ANOVA). The findings were significant at the 0.05 level. The clinical signs significantly changed in the 2, 2.5 and 3 fold BV groups. The hematocrit reduction was significant in the six study groups, corroborating the method effectiveness to promote hemodilution. The laboratorial blood exams significantly changed from 1 fold BV group. The PE was clearly identified by the gravimetric and histological assessment in the 2.5 and 3 fold BV. The respiratory arrest was observed in the 1.5, 2, 2.5 and 3 fold BV groups. The volume of 3 fold BV was lethal to all animals of the group...


Subject(s)
Animals , Male , Rats , Fluid Therapy , Hemodilution , Models, Animal , Pulmonary Edema , Rats, Wistar
2.
Rev. bras. cir. plást ; 23(4): 313-316, out.-dez. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-524876

ABSTRACT

Introdução: Os expansores teciduais representam instrumentos úteis para correção deseqüelas cicatriciais. Neumann (1957) foi o primeiro a publicar relato sobre expansão de pele.Desde então, os expansores vêm sendo utilizados para reparações. Objetivos: Os objetivosdo trabalho são apresentar e avaliar a permeabilidade dos expansores teciduais em estudo“in vitro”. Método: Método 1 - Foram analisados 7 expansores aleatórios em 7 soluçõesdistintas, onde foram mergulhados nas respectivas soluções, preenchidos com ar em seusvolumes totais, encontrados seus períodos de saturação após pesagens, realizado lavado deseu interior com água bidestilada (controle) e enviados para análise. Método 2: Foram unidastais soluções em único frasco, mergulhados 2 expansores aleatórios preenchidos com águabidestilada, aguardados 48 horas e analisadas amostras. Outro frasco foi feito com soluçãode albumina e repetida a mesma metodologia anterior. Resultados: Método 1 - Na análise dosexpansores vazios, a albumina, cloreto, cálcio, fósforo, magnésio e glicose apresentaram-seabaixo do limite de quantificação dos métodos utilizados. O sódio e potássio apresentaramvalores próximos ao limite inferior. Método 2 - Na análise após 48 horas, todos os íonsapresentaram-se abaixo do limite de quantificação, exceto a glicose e o sódio no expansortexturizado em baixíssimo valor pelo método utilizado. Conclusões: O presente estudo sugerepermeabilidade débil ou irrelevante nas análises referidas.


Introduction: The tissues expanders represent useful tools to correct scar’s sequels.Neumann (1957) was the first to publish a report on expansion of skin. Since then theexpanders have been used for repairs. Objectives: The goals of the work are to report andevaluate the permeability of tissues expanders under study “in vitro”. Methods: Method 1- It was analyzed seven different expanders in seven different solutions, where it’s beenimmersed in their respective solutions, filled with air in their totals, found their periods ofsaturations after weighing, when it was done washed of its inside with bidestilated water(control) and sent to analysis. Method 2 - It was put all the solutions together in a single bottle,immersed two aleatory expanders filled with bidestilated water, and after 48 hours, sentsamples to analysis. Another bottle was done with albumin and repeated the same previousmethodology. Results: Method 1 - In the analysis of empty expanders, the albumin, chlorine,calcium, phosphorus, magnesium and glucose performed under to quantification limits of theused methods. The sodium and potassium performed near to lower limit. Method 2 - In theanalysis after 48 hours, all of ions performed under to quantification limit, except the glucoseand sodium in expander texturized were in very low value to used methods. Conclusion: Thepresent work suggests a weak or irrelevant permeability relating to this analysis.


Subject(s)
Biochemistry , In Vitro Techniques , Potassium Permanganate , Tissue Expansion , Methods , Methods
3.
Rev. bras. cir. plást ; 23(3): 179-183, jul.-set. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-517551

ABSTRACT

Introdução: O Etil-2-cianoacrilato (ECA) é um adesivo tecidual utilizado por alguns médicos na prática clínica para fechamento de lesões de pele. São substâncias que se autopolimerizam quando em contato com a ferida, formando uma cola forte e flexível. Este trabalho foi realizado visando à avaliação da eficácia e da biocompatibilidade deste polímero (Epiglu®, da empresa Meyer-Haake, Alemanha) na síntese de pele, em modelo experimental. Método: Dez ratos Wistar machos foram submetidos a três incisões longitudinais no dorso. A incisão central foi tratada com suturade pontos simples de nylon 4.0 (grupo controle), a esquerda com sutura subdérmica de nylon 4.0 associado ao ECA, e a direita apenas o ECA. Os animais foram sacrificados nos dias 3, 7, 14, 21 e 30 pós-operatórios. A biocompatibilidade foi avaliada sob observação direta: necrose, inflamação,dermatite de contato, infecção e deiscência; e à microscopia: reação inflamatória, angiogênese, fibroblastos, colágeno, células gigantes e eosinófilos. Resultados: As sínteses realizadas apenas com o ECA apresentaram maior índice de deiscência (p < 0,05). Todos os outros critérios macro e microscópicos avaliados não apresentaram diferenças estatísticas em relação ao controle (p > 0,05). Conclusão: O uso do ECA é uma boa opção de síntese da pele, com boabiocompatibilidade. Atenção deve ser feita às lesões que apresentem algum grau de tensão, onde a associação com a sutura subdérmica torna-se obrigatória.


Background: The Ethyl-2-cyanoacrylate (ECA) is a synthetic tissue adhesive used by some physicians in clinical practice in wound closures. They polymerize rapidly to adhere tightly toproteinaceous surfaces, form a strong and flexible bond. This study was performed to evaluate the efficacy and biocompatibility of this polymer (Epiglu®, of Meyer-Haake company,Germany) in skin wound closures, in rat model. Methods: Ten male Wistar rats were subjected to three incisions which were closed using different treatments. The central incision was treatedwitch Simple suture of nylon 4.0 (control group). Left incision was treated with sub-dermis suture associated with ECA, and right incision only with ECA. Rats were sacrificed on days 3, 7, 14, 21 and 30 after the intervention. The biocompatibility was evaluated due to direct observation: necrosis, inflammation, dermatitis, infection and dehiscence; and microscopy: inflammatory process, angiogenesis, number of fibroblasts, collagen, giants cells and eosynophils. Results: The wound closured only with ECA presented a higher dehiscence level(p < 0.05). It was not observed another macro or microscopic significant difference comparing to the control group (p > 0.05). Conclusion: The use of the ECA is a good option to the skinclosure, with good biocompatibility. Special attention must receive the wounds with some tension, where the association with a sub-dermis suture becomes imperative.


Subject(s)
Animals , Rats , Cyanoacrylates/analysis , In Vitro Techniques , Intraoperative Complications , Rats, Wistar , Skin , Suture Techniques , Tissue Adhesives , Methods , Diagnostic Techniques and Procedures
4.
Rev. bras. cir. plást ; 23(3): 229-233, jul.-set. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-517560

ABSTRACT

Objetivo: O objetivo do presente trabalho é apresentar os métodos reconstrutivos de anormalidades pós-traumáticas orbitárias, como enxerto ósseo autólogo e retalho osteofascial de fáscia temporoparietal, como alguns dos bons métodos reconstrutivos e como opção terapêutica para esses pacientes. Relato de casos: No presente artigo, relatouse a experiência do uso dos retalhos osteofasciais de fáscia temporoparietal e enxerto ósseoautólogo de calvário na reconstrução das anormalidades orbitárias pós-traumáticas em três casos consecutivos. Conclusão: Com a obtenção de resultados favoráveis e baixa taxa decomplicações no presente trabalho, confirmamos os dados da literatura quanto à supremacia na utilização dos retalhos osteofasciais de fáscia temporoparietal e enxerto ósseo nasreconstruções faciais em casos selecionados.


Purpose: The purpose of the present paper is to present the reconstructive method of posttraumatic orbital abnormalities with osteofascial flaps and bone grafts as an excelentreconstructive method and one more therapeutic option for selected patients. Cases report: The present paper reported the authors experience with the application of the temporoparietalosteofascial flaps or autogenous skull bone graft in the reconstruction of the traumatic orbital abnormalities in three consecutive cases. Conclusions: It was found favorable results with low complications rates. The supremacy of temporoparietal osteofascial flaps andautogenous skull graft in facial reconstructions of selected pacients is confirmed.


Subject(s)
Humans , Male , Adult , Bone Transplantation , Wounds and Injuries/surgery , Orbit/surgery , Surgical Flaps , Transplantation, Autologous , Congenital Abnormalities , Methods , Surgical Procedures, Operative
SELECTION OF CITATIONS
SEARCH DETAIL